  1. ABX Micros CRP 200 - Technical Manual - RAA028A 1–1 Section 01: Introduction 1. Working conditions 1.1. Environment The operation of the ABX Micros CRP 200 should be restricted to indoor location use only! Operation of the instrument at altitudes of over 2000 meters (6000 feet) is not recommended.
  2. ABX Micros 60 - User Manual - RAB042IEN - 7 fABX Micros 60 Place your instrument where it is not exposed to water or vapor. Place your instrument where it is free from vibration or shock.
Micros
  • Hematology

Horiba Abx Micros 60 in Lab Equipment And Accessories for sale used HORIBA ABX Micros 60 for HORIBA ABX Micros HORIBA ABX Micros HORIBA ABX Micros 60: pin. Abx micros 60 manual ABX Micros 60: pin. CDS/ABX Micros 45/60 Micros Diluent CDS/ABX Micros 45/60 Micros Diluent CDS-501-128 (10 Liters) CDS/Micros Diluent (10 Liters) for use with. Micros 60 CS CT Users Manual. The ABX MICROS 60-CS/CT is a fully automated (Microprocessor controlled) Hematology analyzer used for in-vitro diagnostics testing of Whole Blood specimens, Platelet PRP samples, and Whole Blood component concentrates. The ABX MICROS 60-CS/CT is available in 5, 8, 16, and 18 parameters. These parameters are noted according to the system setup.

  • Impedance technology, photometry
  • Microsampling: Only 10 µL
  • No compressor (stepper motor technology)
  • Dedicated infectious disease sample containment for labs

ABX Micros 60 Concept And Technology

  • Measurement methods: Impedance technology, photometry.
  • Liquid valves (without pinching): Reliability and increased precision
  • No compressor (stepper motor): Reliability, less maintenance and noise

Manufactured by HORIBA ABX SAS

Technical

Weight

31 lbs

Power supply

90/240 V - 50/60 Hz - 230 VA.

Dimensions

16.5 in x 14 x 12.5 in (HxWxD).

Printer

Laser Printer

Throughout

60 samples/hour (on open tube)
55 samples/hour (closed tube)

Data management

RS 232 output.
Uni-directional connection.

Memory

LiteDM Patient Data Management System

Screen

2 lines of 40 alphanumerical characters.

Identification

Barcode reader (optional).

Samples

Abx Micros 60 Operators Manual

60 samples/hour (open tube)

Parameters

WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, PLT, MPV, GRA%/#, LYM %/# and MON%/#

Graphics

WBC, RBC and PLT histograms

Sample-Volume

CBC mode: 10 µL

Stability

24 hours (CBC)

Operating mode

Open tube mode with 4 position tube holder (Cal, 125 or 500 µL, 3 or 5 mL)

Identification

Patient I.D., Sequence#

Flags

Pathological flags (WBC, RBC, and PLT) normal limits and counting failure flags

Results

Parameters

Precision (cv %)

Linearity

WBC

< 2,5%

0-100 x 10³/mm3

RBC

< 2%

0-8 x 106/mm3

HGB

< 1.5%

0-26 g/dl

HCT

< 2%

0-80%

PLT (whole blood)

< 5%

0-2200 x 10³/mm3

PLT (PLT concentrate)

< 5%

0-4000 x 10³/mm3

One moment please...
Not A Member?Sign Up
  • Documents
  • Videos
  • News
DESCRIPTION
MicrosAbx micros 60 hematology analyzer8 or 18 fully automated parametersCBC / 3 Part DIFFOpen or Closed Tube

Abx Micros 60 - Manual Pdf

Impedance technology, photometry
Microsampling: Only 10 µL
Smart card based memory storage (optional)
No compressor (stepper motor technology)

Micros 60 Manual

Abx Micros 60 User Manual
FORUMSView All (20)
Ask a New Question

Abx Micros Es 60 User Manual

2

Replies
-frankms123_8300
5 months ago
5 months agoHavingproblem with RDW, Low results

Having problems with low RDW results.RBC 5,09-HGB 15,1-HCT 49,3 MCV 97-MCH 29,7 MCHC 30,66 PLT 230 RDW 2,2.

Reply
-Mkama zebedayo
a year ago
a year agoservicing micro 60 and screen master
i would like to know what can i do to my micro 60 that is giving out high PLT reading that is going up to 22222 sometimes giving DIL.also to my screen master that is giving out a wide range of deviation to a single sample or QC testing sample aslo the failure of QC,How to calibrate this one since it has failed more than fifth times?Reply

2

Replies
-Trelaone
2 years ago
2 years agoSERVICE MANUAL
Dear All,Am looking for a service manual for Horiba ABX Micros 60. May anyone who has it share by sending to: vgmakwinja@medcol.mwThanks in advance.Reply
SERVICE COMPANIESView All Hematology Analyzer Companies

FEATURES

Measurement methods: Impedance technology, photometry. Liquid valves (without pinching): Reliability and increased precision No compressor (stepper motor): Reliability, less maintenance and noise

Micros

Additional Specifications

Technical
Weight
31 lbs
Power supply
90/240 V - 50/60 Hz - 230 VA.
Dimensions
16.5 in x 14 x 12.5 in (HxWxD).
Printer
Dot matrix.
Throughout
60 samples/hour (on open tube)
55 samples/hour (closed tube)
Data management
Automated smart cards used for QC and patient data storage (optional).
RS 232 output.
Mono-directional connection.
Memory
Last result (with curves) or 78 results (optional smart cards based memory)

Screen

2 lines of 40 alphanumerical characters.
Keyboard
Barcode reader (optional).
Samples
60 samples/hour (open tube)
Parameters (16+2)
CBC Mode (18 parameters): WBC, RBC, HGB, HCT, MCV,*RDW, MCH, MCHC, PLT, MPV, PCT, *PDW, % and # of LYM, MON and GRA
Graphics
LMG histogram, RBC, PLT histograms
Sample-Volume
CBC mode : 10 µL
Stability
24 hours (CBC)
Operating sample mode
Open tube mode with 4 position tube holder (QC, 125 or 500 µL, 3 or 5 mL)
Identification
Patient I.D., Sequence#
Flags
Pathological flags (WBC, RBC, and PLT) normal limits and counting failure flags
* RUO (Research Use Only)